List of BIS Laboratories


Date :-

Lab Quantity Lab Type Testing Facility Remarks
IS Number :- IS 60947 - 3 : 1999
 CL  NA  Elec  N  (updated on 06.09.2016)
IS Number :- IS 60947 - 4 : 2000
 CL  NA  Elec  N  (updated on 06.09.2016)
IS Number :- IS 60947 - 5 : 2003
 CL  NA  Elec  N  (updated on 06.09.2016)

Record not found !
IS No. Testing Charges Remarks



Testing Facility:: C=Complete Test facility / P=Partial Test Facility/ N=No Test Facility


List of Outside Recognized Laboratories



      IS Number :- IS 60947 Part: 2 Year: 16 - Low - Voltage switchgear and controlgear: Part 2 circuit - Breakers (First Revision)
Sl No. Name of the Recognized Laboratory Lab Code Testing Charges Remarks
1
Central Power Research Insititue,
Switchgear Testing & Development Station,
Govindpura,
BHOPAL-462023
Madhya Pradesh
Contact : Dr. A.K. Datta, JD
Tel : 91-0755-2586682
Fax : 91-0755-2587774
Email: arun@cpri.in, stds@cpri.in
8100924
Rs. 4337830/-
Included w.e.f. 08.04.2024 Exclusion:Cl. 8.3.9 (Critical d.c. load current test), Cl. B.8.7 (Behavior in the case of an earth fault current comprising a d.c. component), Cl. B.8.8 (Behavior in the case of failure of line voltage for CBRs classified under B.3.1.2.1), Cl. B.8.9 (Behavior in the case of failure of line voltage for CBRs classified under B.3.1.2.2), Cl. 7.3 Annexure J Table J.1 (Electrostatic discharges, Radiated radio-frequency electromagnetic fields, Electrical fast transients/bursts, Surges, Conducted disturbances induced by radio frequency fields, Power frequency magnetic fields, Voltage dips and interruptions), Cl. 7.3 Annexure J Table J.3 ("Conducted RF disturbances 150 kHz to 30 MHz", Radiated RF disturbances 30 MHz to 1 000 MHz
2
Central Power Research Institute
Prof.Sir C.V.Raman Road, Sadashivanagar,
Sub Post Office, P.B. No.8066,
Bangalore-560080
Karnataka
Contact : Sh. T. Bhavani Shankar, JD
Tel : 080-23602457
Fax : 080-23605367
Email: tbs@cpri.in
6101024
For all test sequences Rs.579250/-; Test Sequence I: Rs.188550/-; Test Sequence II: Rs.94850/-; Test Sequence III: Rs.64350/-; Test Sequence IV: Rs.110650/-; Test Sequence V: Rs.120850/-; Combined test Sequence : Rs.143900/-
REVISED VERSION OF IS 60947(PART-2):2016 INCLUDED W.E.F. 10-06-2021.
3
Electrical Research & Development Association
P.B. No. 760, ERDA Road,
GIDC, Makarpura Industrial Estate
Vadodara-390010
Gujarat
Contact : Dr. Satish H. Chetwani, Incharge
Tel : 0265-2642942,964,377
Fax : 0265-2648382
Email: erda@erda.org, vinod.gupta@erda.org, mitesh.prajapati@erda.org
7101125
Test sequence – I (Up to 200A AC)= Rs. 1,15,850/- Test sequence – I (201 to 1000A AC)= Rs. 1,46,185/- Test sequence – I (1001 to 2000A AC)= Rs. 1,77,494/- Test sequence – I (2001 to 6300A AC)= Rs. 7,31,815/- Test sequence – I (Up to 100A AC)= Rs. 1,89,725/- Test sequence – I (101 to 315A DC)= Rs. 1,99,525/- Test sequence – I (3016 to 630A DC)= Rs. 2,04,525/- Test sequence – I (631 to 2000A DC)=Rs. 2,27,425/- Test sequence – II (Up to 50kA)= Rs. 1,81,524/- Test sequence – II (Above 50kA to 80kA)= Rs. 2,31,032/- Test sequence – II (Above 80kA to 120kA)= Rs. 4,55,282/- Test sequence – III (Up to 50kA)= Rs. 1,85,089/- Test sequence – III (Above 50kA to 80kA)= Rs. 2,18,094/- Test sequence – III (Above 80kA to 120kA)= Rs. 3,67,594/- Test sequence – IV (Up to 50kA)= Rs. 3,16,476/- Test sequence – IV (Above 50kA to 80kA)=Rs. 3,96,344/- Test sequence – IV (Above 80kA to 120kA)= Rs. 7,17,194/- Test sequence – V (Up to 50kA)= Rs. 3,32,228/- Test sequence – V (Above 50kA to 80kA)= Rs. 3,98,238/- Test sequence – V (Above 80kA to 120kA)= Rs. 6,97,238/- Test sequence – VI (Up to 50kA)= Rs. 3,50,861/- Test sequence – VI (Above 50kA to 80kA)= Rs. 4,47,232/- Test sequence – VI (Above 80kA to 120kA)= Rs. 8,42,832/- Routine Test= Rs. 67,757/- Annexure B= Rs. 65,838/- Annexure C (Up to 50kA)= Rs. 93,779/- Annexure C (Above 50kA to 80kA)= Rs. 1,10,282/- Annexure C (Above 80kA to 120kA)= Rs. 1,85,032/- Annexure H (Up to 50kA)= Rs. 69,593/- Annexure H (Above 50kA to 80kA)= Rs. 1,02,599/- Annexure H (Above 80kA to 120kA)= Rs. 2,52,098/- Annexure J= Rs. 1,30,400/-
Included w.e.f. 19.07.2023. Exclusion: Cl.B.8.8 (Voltage) Behaviour in the case of failure of line voltage for CBRs classified under B.3.1.2.1, Cl. Cl.B.8.9 (Voltage) Behaviour in the case of failure of line voltage for CBRs classified under B.3.1.2.2
4
GIGA LABS
BEARYS GLOBAL RESEARCH CENTRE, 63/3B
GORVIGERE VILLAGE, BIDARAHALLI HOBLI
BENGALURU-560067
Karnataka
Contact : Rachna Verma
Tel : 9663819234
Fax :
Email: mirunaashree.manoharan@se.com
6177526
Rs. 625000/-
Exclusion: Cl.8.3.9 (Critical d.c. load current test), Cl.8.3.7.2 (Short-circuit at the selectivity limit current), Cl.8.3.7.6 ((stage 2) short circuit at 1.1 time the take-over current (sequence V)), Cl.8.3.7.7 (Short-circuit at ultimate short-circuit breaking capacity), Cl.8.3.6.5 (Short-circuit breaking capacity at maximum short-time withstand current), Cl.8.3.6.3 (Rated short-time withstand current), Cl.8.3.8.3 (Rated short-time withstand current)
5
Novateur Electrical and Digital Systems Pvt Ltd
A-2, MIDC Malegaon, Sinnar,

Nashik-422113
Maharashtra
Contact : TUSHAR B. DHAKE, Manager
Tel : 8657926870
Fax :
Email: nedspl.lab@legrand.com
7176426
Rs.1086000/-
Exclusion: Cl.7.3 Annexure J Table J.1 (Electrostatic discharges), Cl.7.3 Annexure J Table J.1 ("Radiated radio-frequency electromagnetic fields"), Cl.7.3 Annexure J Table J.1 ("Electrical fast transients/bursts"), Cl.7.3 Annexure J Table J.1 ("Radiated radio-frequency electromagnetic fields"), Cl.7.3 Annexure J Table J.1 (Surges), Cl.7.3 Annexure J Table J.1 ("Conducted disturbances induced by radio frequency fields"), Cl.7.3 Annexure J Table J.1 ("Power frequency magnetic fields"), Cl.7.3 Annexure J Table J.1 ("Voltage dips and interruptions"), Cl.7.3 Annexure J Table J.3 ("Conducted RF disturbances 150 kHz to 30 MHz"), Cl.7.3 Annexure J Table J.3 ("Radiated RF disturbances 30 MHz to 1 000 MHz"), B.8.6 (Resistance against unwanted tripping due to surge currents resulting from impulse voltage), Cl.B.8.7 (Behavior in the case of an earth fault current comprising a d.c. component), Cl.8.3.9 (Critical d.c. load current test)
6
SWITCHGEAR TESTING LABORATORIES-MSW
SCHNEIDER ELECTRIC (I)Pvt. Ltd.PLOT NO. - A600
TTC INDUSTRIAL AREA, MIDC SHIL-PHATA ROAD
MAHAPE, Mumbai-400710
Maharashtra
Contact : Mr. Virender Singh Bura, Lab Head
Tel : 9987796162
Fax :
Email: somnath.borate@lntebg.com
7177626
Rs. 642700/-
Exclusion: Cl.7.3 Annexure J Table J.1 (Electrostatic discharges, Radiated radio-frequency electromagnetic fields, Electrical fast transients/bursts, Radiated radio-frequency electromagnetic fields, Surges, Conducted disturbances induced by radio frequency fields, Power frequency magnetic fields, Voltage dips and interruptions), Cl.7.3 Annexure J Table J.3 (Conducted RF disturbances 150 kHz to 30 MHz, Radiated RF disturbances 30 MHz to 1 000 MHz)
7
TYPE TEST CENTER SIEMENS LIMITED KALWA
SIEMENS LIMITED, KALWA WORKS, THANE
BELAPUR ROAD
Navi Mumbai-400708
Maharashtra
Contact : Mr. Neelesh Kayal (Test Design Professional)
Tel : 9820055702
Fax :
Email: ttcslkw.in@siemens.com
7174421
Rs 494938/-
Exclusion : Cl.8.3.6.5 (short circuit breaking capacity at maximum short time withstand current (sequence IV)), Cl.8.3.6.2 (verification of overload releases (sequence IV)), Cl.8.3.6.3 (rated short circuit withstand current (sequence IV)), Cl.8.3.6.4 (verification of temperature-rise (sequence IV)), Cl.8.3.6.6 (verification of dielectric withstand (sequence IV)), Cl.8.3.6.7 (verification of overload releases (sequence IV)), Cl.8.3.7.1 (General), Cl.8.3.7.2 (Short-circuit at the selectivity limit current), Cl.8.3.7.3 ((stage 1) verification of temperature-rise (sequence V)), Cl.8.3.7.4 ((stage 1) verification of dielectric withstand (sequence V)), Cl.8.3.7.5 ((stage 2) verification of overload releases (sequence V)), Cl.8.3.7.6 ((stage 2) short circuit at 1.1 time the take-over current (sequence V)), Cl.8.3.7.7 ((stage 2) short circuit at rated ultimate short circuit breaking capacity (sequence V)), Cl.8.3.7.8 ((stage 2) verification of dielectric withstand (sequence V)), Cl.8.3.7.9 (Verification of Overload releases), Cl.8.3.9 (Critical d.c. load current test), Cl. 7.3 Annexure J Table J.1 (Electrostatic discharges), Cl. 7.3 Annexure J Table J.1 ("Radiated radio-frequency electromagnetic fields"), Cl. 7.3 Annexure J Table J.1 ("Electrical fast transients/bursts"), Cl. 7.3 Annexure J Table J.1 ("Radiated radio-frequency electromagnetic fields"), Cl. 7.3 Annexure J Table J.1 (Surges), Cl. 7.3 Annexure J Table J.1 ("Conducted disturbances induced by radio frequency fields"), Cl. 7.3 Annexure J Table J.1 ("Power frequency magnetic fields"), Cl. 7.3 Annexure J Table J.1 ("Voltage dips and interruptions"), Cl. 7.3 Annexure J Table J.3 ("Conducted RF disturbances 150 kHz to 30 MHz"), Cl. 7.3 Annexure J Table J.3 ("Radiated RF disturbances 30 MHz to 1 000 MHz")
8
UL India Pvt Ltd
Loc 1&2-Kalyani Platina Campus Whitefield
Loc3- 30/A Ist Stage Doddanekkundi Indl. Area
Bangalore-560066
Karnataka
Contact : Ms Vinutha MU Quality Manager
Tel : 080-41384400
Fax : 080-08028413759
Email: Vinutha.mu@ul.com
6120526
Rs.8,33,400/- for SP/SPN/DP, Rs.9,87,500/- For TP/TPN/FP (For 1 set o fsamples for all sequences)
Included w.e.f. 24-02-2022.
9
UL India Pvt Ltd
Loc 1&2-Kalyani Platina Campus Whitefield
Loc3- 30/A Ist Stage Doddanekkundi Indl. Area
Bangalore-560066
Karnataka
Contact : Ms Vinutha MU Quality Manager
Tel : 080-41384400
Fax : 080-08028413759
Email: Vinutha.mu@ul.com
6120526
Rs. 1682500/-
Included w.e.f. 09.04.2024 Exclusion: Cl. 8.3.9 (Critical d.c. load current test), Annex P (DC circuit-breakers for use in photovoltaic (PV) applications), Cl.8.5 (Annex Q of IS/IEC 60947-1) (Special tests), Annex G (Power loss), Annex L (Circuit-breakers not fulfilling the requirements for overcurrent protection), Annex M (Modular residual current devices (without integral current breaking device)), Annex N (Electromagnetic compatibility (EMC)), Annex O (Electromagnetic compatibility (EMC)), Annex R (Circuit-breakers incorporating residual current protection with automatic re-closing functions)


      IS Number :- IS 60947 Part: 3 Year: 93 - IS/IEC 60947(Part-3):1999 - Low-Voltage switchgear and controlgear : Part 3 Switchgears, disconnectors, switch-disconnectors and fuse combination units
Sl No. Name of the Recognized Laboratory Lab Code Testing Charges Remarks
1
Central Power Research Insititue,
Switchgear Testing & Development Station,
Govindpura,
BHOPAL-462023
Madhya Pradesh
Contact : Dr. A.K. Datta, JD
Tel : 91-0755-2586682
Fax : 91-0755-2587774
Email: arun@cpri.in, stds@cpri.in
8100924
For STC tests upto 50 kA : for rating upto 100A - Rs.3,27,750/- (DP), Rs.3,50,600/- (TP), Rs.3,85,300/- (TPN); for rating 101A to 200A - Rs.3,26,421/- (DP), Rs.3,49,271/- (TP), Rs.3,83,971/- (TPN); for rating 201A to 630A - Rs.3,21,800/- (DP), Rs.3,49,621/- (TP), Rs.3,84,350/- (TPN); for rating 631A to 2500A - Rs.5,94,700/- (DP), Rs.6,17,550/- (TP), Rs.6,51,300/- (TPN); For STC test 51 kA to 80 kA : for rating upto 100A - Rs.3,99,600/- (DP), Rs.4,22,450/- (TP), Rs.4,57,150/- (TPN); for rating 101A to 200A - Rs.3,98,271/- (DP), Rs.4,21,121/- (TP), Rs.4,55,821/- (TPN); for rating 201A to 630A - Rs.3,98,650/- (DP), Rs.4,21,502/- (TP), Rs.4,56,200/- (TPN); for rating 631A to 2500A - Rs.7,63,550/- (DP), Rs.7,68,600/- (TP), Rs.8,11,560/- (TPN).

2
Central Power Research Insititue,
Switchgear Testing & Development Station,
Govindpura,
BHOPAL-462023
Madhya Pradesh
Contact : Dr. A.K. Datta, JD
Tel : 91-0755-2586682
Fax : 91-0755-2587774
Email: arun@cpri.in, stds@cpri.in
8100924
Rs. 19,09,950/-
scope restricted to testing except UTILIZATION category DC as per Annex A
3
Central Power Research Institute
Prof.Sir C.V.Raman Road, Sadashivanagar,
Sub Post Office, P.B. No.8066,
Bangalore-560080
Karnataka
Contact : Sh. T. Bhavani Shankar, JD
Tel : 080-23602457
Fax : 080-23605367
Email: tbs@cpri.in
6101024
For all test sequences Rs.307700/-; Test Sequence I: Rs.118300/-; Test Sequence II: Rs.49200/-; Test Sequence III: Rs.70100/-;Test Sequence IV: Rs.70100/-
REVISED VERSION OF IS 60947(PART-3):2012 INCLUDED W.E.F. 10-06-2021.
4
Electrical Research & Development Association
P.B. No. 760, ERDA Road,
GIDC, Makarpura Industrial Estate
Vadodara-390010
Gujarat
Contact : Dr. Satish H. Chetwani, Incharge
Tel : 0265-2642942,964,377
Fax : 0265-2648382
Email: erda@erda.org, vinod.gupta@erda.org, mitesh.prajapati@erda.org
7101125
Rs. 2,11,308/- (For complete tests except extra tests) [One rating : Seq I Rs. 71,926/- ; Seq II Rs. 52,319/- ; Seq III Rs. 1,30,519/- ; Seq IV Rs. 1,30,519/- ; Seq V Rs. 20,838/- ; Routine tests : Rs. 1,161/-; Other tests Rs. 62,100/-] ; Extra tests Rs. 1,61,505/- .

5
UL India Pvt Ltd
Loc 1&2-Kalyani Platina Campus Whitefield
Loc3- 30/A Ist Stage Doddanekkundi Indl. Area
Bangalore-560066
Karnataka
Contact : Ms Vinutha MU Quality Manager
Tel : 080-41384400
Fax : 080-08028413759
Email: Vinutha.mu@ul.com
6120526
Rs.3,90,200/- for SP/SPN/DP, Rs.4,46,700/- For TP/TPN/FP (For 1 set o fsamples for all sequences)
Included w.e.f. 24-02-2022.
6
UL India Pvt Ltd
Loc 1&2-Kalyani Platina Campus Whitefield
Loc3- 30/A Ist Stage Doddanekkundi Indl. Area
Bangalore-560066
Karnataka
Contact : Ms Vinutha MU Quality Manager
Tel : 080-41384400
Fax : 080-08028413759
Email: Vinutha.mu@ul.com
6120526
Rs. 1536200/-
Included w.e.f. 09.04.2024 Exclusion: Cl.8.2.1.1.2 (Test of resistance to abnormal heat and fire), Cl.8.2.3 (Enclosures for equipment)


      IS Number :- IS 60947 Part: 4 Sec: 1 Year: 00 - IS/IEC 60947(Pt-4/Sec-1):2000 --Low Voltage Switchgear and Controlgear - Part 4 : Contractors and Motor-Starters - Section 1 : Electromechanical Contractors and Motors-Starters
Sl No. Name of the Recognized Laboratory Lab Code Testing Charges Remarks
1
Central Power Research Insititue,
Switchgear Testing & Development Station,
Govindpura,
BHOPAL-462023
Madhya Pradesh
Contact : Dr. A.K. Datta, JD
Tel : 91-0755-2586682
Fax : 91-0755-2587774
Email: arun@cpri.in, stds@cpri.in
8100924
Rating Upto 63A : Rs.2,29,850/- for test current upto 50 kA, Rs.2,52,325/- for test current 50 kA to 80 kA; Rating 64A to 150A: Rs.2,54,850/- for test current upto 50 kA, Rs.2,77,325/- for test current 50 kA to 80 kA; Rating 151A to 200A: Rs.2,54,850/- for test current upto 50 kA, Rs.2,77,325/- for test current 50 kA to 80 kA; Rating 201A to 300A: Rs.2,58,050/- for test current upto 50 kA, Rs.2,80,525/- for test current 50 kA to 80 kA; Rating 301A to 400A: Rs.4,35,550/- for test current upto 50 kA, Rs.4,58,025/- for test current 50 kA to 80 kA; Rating 401A to 500A: Rs.4,71,100/- for test current upto 50 kA, Rs.4,93,575/- for test current 50 kA to 80 kA; Rating 501A to 650A: Rs.5,75,300/- for test current upto 50 kA, Rs.5,97,775/- for test current 50 kA to 80 kA; Rating 651A to 800A: Rs.6,64,175/- for test current upto 50 kA, Rs.6,86,650/- for test current 50 kA to 80 kA; Rating 801A to 1000A: Rs.7,85,475/- for test current upto 50 kA, Rs.8,07,950/- for test current 50 kA to 80 kA; Rating 1001A to 1666A: Rs.7,98,325/- for test current upto 50 kA, Rs.8,20,800/- for test current 50 kA to 80 kA; Rating 1667A to 2000A: Rs.7,88,325/- for test current upto 50 kA, Rs.81,800/- for test current 50 kA to 80 kA; Rating 2001A to 3000A: Rs.7,91,375/- for test current upto 50 kA, Rs.8,13,850/- for test current 50 kA to 80 kA; Rating 3001A to 4000A: Rs.8,04,975/- for test current upto 50 kA, Rs.8,27,450/- for test current 50 kA to 80 kA

2
Central Power Research Insititue,
Switchgear Testing & Development Station,
Govindpura,
BHOPAL-462023
Madhya Pradesh
Contact : Dr. A.K. Datta, JD
Tel : 91-0755-2586682
Fax : 91-0755-2587774
Email: arun@cpri.in, stds@cpri.in
8100924
Testing charges sequence wise: Test Sequence 1 : 93050/- Test sequence 2 : 280000/- Test sequence 3 : 460000/- Test sequence 4 (applicable to contactors only): 380400/- Test sequence 5 : 61600/-

3
Central Power Research Institute
Prof.Sir C.V.Raman Road, Sadashivanagar,
Sub Post Office, P.B. No.8066,
Bangalore-560080
Karnataka
Contact : Sh. T. Bhavani Shankar, JD
Tel : 080-23602457
Fax : 080-23605367
Email: tbs@cpri.in
6101024
For all test sequences Rs.294850/- (Contactor), Rs.348950/- (Starters) Test Sequence I: Rs.23050/- (Contactor), Rs.77150/- (Starter); Test Sequence II: Rs.94150/-; Test Sequence III: Rs.103300/-; Test Sequence IV: Rs.35550/-; Test Sequence IV: Rs.38800/-
REVISED VERSION OF IS 60947(PART-4/SEC-1):2012 INCLUDED W.E.F. 10-06-2021.
4
Electrical Research & Development Association
P.B. No. 760, ERDA Road,
GIDC, Makarpura Industrial Estate
Vadodara-390010
Gujarat
Contact : Dr. Satish H. Chetwani, Incharge
Tel : 0265-2642942,964,377
Fax : 0265-2648382
Email: erda@erda.org, vinod.gupta@erda.org, mitesh.prajapati@erda.org
7101125
Rs. 4,55,661/- (For complete testing) One rating : Seq I Rs. 57,128/- ; Seq II Rs. 80,500/- ; Seq III Rs. 60,800/- ; Seq IV : Rs. 9,200/- ; Seq V Rs. 8,286/- ; Routine test Rs. 20,205/- ; Annexure-B Rs. 60,375/- ; Annexure-F Rs. 10,786/- ; Other tests Rs. 88,500/- ; Extra tests Rs. 59,881/- .
Exclusion: Cl. 9.3.3.3.8 (Temperature rise of starting resistors for rheostatic rotor starters), Cl. 9.3.3.3.9 ( Temperature rise of the auto-transformer for two-step auto-transformer starters)
5
UL India Pvt Ltd
Loc 1&2-Kalyani Platina Campus Whitefield
Loc3- 30/A Ist Stage Doddanekkundi Indl. Area
Bangalore-560066
Karnataka
Contact : Ms Vinutha MU Quality Manager
Tel : 080-41384400
Fax : 080-08028413759
Email: Vinutha.mu@ul.com
6120526
Rs.3,70,800/- for 1 sample

6
UL India Pvt Ltd
Loc 1&2-Kalyani Platina Campus Whitefield
Loc3- 30/A Ist Stage Doddanekkundi Indl. Area
Bangalore-560066
Karnataka
Contact : Ms Vinutha MU Quality Manager
Tel : 080-41384400
Fax : 080-08028413759
Email: Vinutha.mu@ul.com
6120526
rs.5,19,120/- (For 1 set of samples for all sequences)
Included w.e.f. 24-02-2022.
7
UL India Pvt Ltd
Loc 1&2-Kalyani Platina Campus Whitefield
Loc3- 30/A Ist Stage Doddanekkundi Indl. Area
Bangalore-560066
Karnataka
Contact : Ms Vinutha MU Quality Manager
Tel : 080-41384400
Fax : 080-08028413759
Email: Vinutha.mu@ul.com
6120526
Rs. 2064566/-
Included w.e.f. 09.04.2024 Exclusion: Cl.8.1.2.3 (Test based on flammability category), Cl.9.1.2 (j) (Annex C of IEC 60947-1) (verification of degrees of protection of enclosed contactors and starters), Cl.9.1.5.2 (Annex Q of IS/IEC 60947-1) (Special tests)


      IS Number :- IS 60947 Part: 5 Sec: 1 Year: 09 - IS/IEC 60947(Pt-5/Sec-1):2003 -- Low Voltage Switchgear and Controlgear - Part 5 : Control Circuit Devices and Switching Elements - Section 1 : Electromechanical Control Circuit Devices
Sl No. Name of the Recognized Laboratory Lab Code Testing Charges Remarks
1
Electrical Research & Development Association
P.B. No. 760, ERDA Road,
GIDC, Makarpura Industrial Estate
Vadodara-390010
Gujarat
Contact : Dr. Satish H. Chetwani, Incharge
Tel : 0265-2642942,964,377
Fax : 0265-2648382
Email: erda@erda.org, vinod.gupta@erda.org, mitesh.prajapati@erda.org
7101125
Rs. 1,01,962/- (For complete tests) (One rating : Seq I Rs. 14,121/- ; Seq II Rs. 25,811/- ; Seq III Rs. 16,899/- ; Seq IV Rs. 31,216/- ; Seq V Rs. 10,264/- ; Seq VI Rs. 3,651/-)

2
UL India Pvt Ltd
Loc 1&2-Kalyani Platina Campus Whitefield
Loc3- 30/A Ist Stage Doddanekkundi Indl. Area
Bangalore-560066
Karnataka
Contact : Ms Vinutha MU Quality Manager
Tel : 080-41384400
Fax : 080-08028413759
Email: Vinutha.mu@ul.com
6120526
Rs.3,65,650/- for 1 sample

3
UL India Pvt Ltd
Loc 1&2-Kalyani Platina Campus Whitefield
Loc3- 30/A Ist Stage Doddanekkundi Indl. Area
Bangalore-560066
Karnataka
Contact : Ms Vinutha MU Quality Manager
Tel : 080-41384400
Fax : 080-08028413759
Email: Vinutha.mu@ul.com
6120526
Rs. 2431000/-
Included w.e.f. 09.04.2024 Exclusion: J.8.5 (Degree of protection for indicating towers), Annex C of IEC 60947-1 (Degree of protection of enclosed control circuit devices)


      IS Number :- IS 60947 Part: 5 Sec: 5 Year: 16 - Low - Voltage switchgear and controlgear: Part 5 control circuit devices and switching elements: Sec 5 electrical emergency stop devices with mechanical latching function
Sl No. Name of the Recognized Laboratory Lab Code Testing Charges Remarks
1
UL India Pvt Ltd
Loc 1&2-Kalyani Platina Campus Whitefield
Loc3- 30/A Ist Stage Doddanekkundi Indl. Area
Bangalore-560066
Karnataka
Contact : Ms Vinutha MU Quality Manager
Tel : 080-41384400
Fax : 080-08028413759
Email: Vinutha.mu@ul.com
6120526
Rs. 1809302/-
Included w.e.f. 09.04.2024 Exclusion: Cl. 5.3 (Degrees of protection of enclosed equipment)